Calculation Methodology & Engineering Assumptions
Every calculator on WattCalc uses deterministic electrical formulas calibrated against manufacturer specifications and real-world inverter efficiency curves.
1. AC vs. 12V DC Efficiency
Converting DC battery cells to 120V AC household power consumes inverter standby overhead and conversion heat. We model 85% usable AC efficiency (`Capacity Wh × 0.85 ÷ Average Watts`) and 92% usable 12V DC / USB-C efficiency (`Capacity Wh × 0.92 ÷ DC Watts`).
2. Compressor Duty Cycles
Devices like refrigerators, chest freezers, and window ACs do not pull full wattage 100% of the time. WattCalc separates Active Running Watts (checked against the continuous inverter limit) from Duty-Cycled Average Watts (used for runtime hours).
3. Startup Surge Verification
Inductive motors (refrigerators, sump pumps, AC compressors) demand 2×–3× their running wattage for 100–500 milliseconds on startup. A station is flagged Overload if either continuous watts exceed the AC continuous rating or startup surge exceeds the AC surge ceiling.
4. Real-World Solar Derating (78%)
Portable solar panels rarely produce 100% of their lab STC sticker rating due to sun angle, panel heat, and MPPT conversion losses. WattCalc multiplies rated solar input by 0.78 to estimate realistic peak-sun charging watts.
FTC Affiliate Disclosure
WattCalc provides free engineering calculators supported by display advertising and affiliate links. When you click a retailer button (such as Amazon) and make a qualifying purchase, WattCalc may earn a commission at no extra cost to you. Compatibility verdicts and runtime outputs are strictly mathematical and are never altered for commercial partners.